← All posts

How Many BP3800 Do I Need? Sizing by Outage Hours

2026-11-18 · Sun Solvers

Short answer: Multiply your average backup load in watts by the outage hours you want to cover, add a buffer, divide by 3,840Wh, and subtract one for the F3800 itself. Example: a 300W average for 48 hours with a 15% buffer works out to about 16,900Wh, or an F3800 plus 4 BP3800s. One F3800 or F3800 Plus takes up to six (Anker support).

Some outages in Las Vegas are over quickly. Others last long enough to put the food in your fridge at risk. Ready.gov says a closed refrigerator keeps food cold for about four hours, and a full freezer holds its temperature for about 48 hours. Once an outage runs past that, a battery that keeps the fridge running is the difference between saving groceries and throwing them out. The question is how much battery. Here is how to size it from your own numbers, not a guess.

Why outage hours, not appliance count, decide the number

A BP3800 adds capacity (watt-hours), not output. Anker's user guide says the BP3800 can't be used by itself; it has to be connected to an F3800 or F3800 Plus, which does the charging and powers your outlets. So adding batteries doesn't let you run bigger appliances. It lets you run the same ones for longer.

That makes the real question "how many hours, at what average draw?" A fridge, a router and a few lights might average a few hundred watts. Run that for 12 hours and you're well within one F3800. Run it for two or three days without recharging and you need more battery.

Don't forget the power station's own draw. Our Products page lists the F3800 Plus at about 40W idle with AC on. Over 24 hours that's about 960Wh (40W × 24, a calculation), which is a quarter of a BP3800 every day before your fridge uses anything.

How to size your BP3800 count: 6 steps

  1. List what must stay on. Usually the fridge, any freezer, Wi-Fi, some lights, phone charging and medical devices. Ready.gov suggests taking an inventory of everything you rely on that needs electricity.
  2. Find each item's watts. Virginia Cooperative Extension says wattage is usually stamped on the bottom or back of an appliance or on its nameplate; if only amps are listed, multiply amps by volts (most U.S. appliances use 120V). For a fridge, Extension notes the compressor cycles, so estimate full-wattage hours as about one-third of the time it's plugged in. A plug-in energy meter left on for 24 hours gives a more realistic number. Our F3800 fridge runtime guide walks through this.
  3. Get one average-watts number. Add up daily watt-hours (watts × hours used per day), including about 40W for the F3800 Plus itself, then divide by 24.
  4. Pick your outage hours. 12 hours covers an overnight outage. 48 to 72 hours covers a longer event without recharging. Our multi-day outage guide explains what changes after the first night.
  5. Do the math with a buffer. Total Wh = average watts × hours. Inverter efficiency isn't listed in our comparison data, so leave room: this post uses a 15% planning buffer (divide by 0.85) as an assumption you can change. Divide the result by 3,840Wh, round up, and subtract one for the F3800 or F3800 Plus itself. That's your BP3800 count.
  6. Check where they'll live. Each BP3800 weighs 72 lb and measures 15.5 × 14.0 × 10.3 in. Anker lists a charging range of 32°F to 104°F and a discharging range of -4°F to 104°F, so pick a spot that stays inside it.

BP3800 capacity and runtime by setup

Hours are raw capacity ÷ average load, before losses. Apply your own buffer.

Setup Total capacity Hours at 300W average Hours at 600W average Type Source
F3800 or F3800 Plus alone 3,840Wh 12.8 6.4 Calculation Anker F3800 Plus page; Sun Solvers Products page
+ 1 BP3800 7,680Wh 25.6 12.8 Calculation Sun Solvers Products page (F3800 + Expansion Battery bundle)
+ 2 BP3800 11,520Wh 38.4 19.2 Calculation 3,840Wh × 3
+ 3 BP3800 15,360Wh 51.2 25.6 Calculation 3,840Wh × 4
+ 4 BP3800 19,200Wh 64.0 32.0 Calculation 3,840Wh × 5
+ 5 BP3800 23,040Wh 76.8 38.4 Calculation 3,840Wh × 6
+ 6 BP3800 (max per unit) 26,880Wh (about 26.9kWh) 89.6 44.8 Calculation Anker support; Sun Solvers Products page
F3800 Plus idle draw About 40W with AC on — — Spec Sun Solvers Products page
F3800 Plus idle energy per day About 960Wh — — Calculation 40W × 24 hours
Worked example: 300W for 48 hours, 15% buffer About 16,941Wh needed 4.41 units, round up to 5 F3800 + 4 BP3800 Calculation 300 × 48 ÷ 0.85 ÷ 3,840
Food in a closed fridge / full freezer About 4 hours / about 48 hours — — Guidance Ready.gov Power Outages

BP3800 sizing checklist

Frequently asked questions

How many BP3800 batteries can connect to one F3800?

Up to six. Anker's support articles say each F3800 and each F3800 Plus can connect up to six BP3800 expansion batteries, and the BP3800 user guide says the same. With six, one unit reaches 26,880Wh, about 26.9kWh.

Can a BP3800 power anything on its own?

No. Anker's user guide says the expansion battery can't be used by itself and must be connected to the power station for charging and discharging. It works with the F3800 and F3800 Plus only.

Do more BP3800 batteries let me run bigger appliances?

No. They add hours, not watts. Output still comes from the F3800 or F3800 Plus, which our Products page lists at 6,000W. Check that everything running at once stays under that before adding batteries for runtime.

How do I recharge several BP3800s after an outage?

Through the power station. Anker's guide says the expansion battery charges after the power station is full. The F3800 Plus accepts up to 3,200W of solar (two 1,600W inputs) and 1,800W from a wall outlet, per Anker. Generator charging reaches 6,000W only with one or more expansion batteries connected (3,300W for a single unit), and Anker's generator adapter is required.

How long will food last in my fridge without power?

Ready.gov says a closed refrigerator keeps food cold for about four hours and a full freezer holds temperature for about 48 hours. Keep the doors closed, watch the temperature, and throw out food that reaches 40°F or higher.

What should I unplug when the power comes back?

Ready.gov notes that power may return with momentary surges or spikes that can damage equipment, and suggests turning off or disconnecting appliances and electronics during an outage. Plug things back in after power is steady.

Book a backup consult

Bring your list of must-run items and a recent power bill to Sun Solvers at 3201 Sunrise Ave in Las Vegas, or call (702) 296-7300. Book a backup consult and we'll size the F3800 or F3800 Plus and the right number of BP3800 batteries against your real loads. You can also compare models on our Products page and the F3800 vs F3800 Plus guide.